A real oak floor is still the finish everything else imitates. We supply and fit both engineered oak, which is built in layers so it stays stable over underfloor heating, and solid oak, which is a single piece of timber that can be sanded back and refinished for decades.
Both are supplied and fitted across Preston, Longridge, Chorley, Blackburn and the surrounding Lancashire villages, in plank widths from narrow strip through to wide board, and in patterns including herringbone and chevron.
Engineered oak has a genuine oak wear layer bonded to a plywood core running at right angles beneath it. That construction stops the board cupping or gapping as the humidity in a house changes through the year, which makes it the right choice over underfloor heating and on concrete subfloors.
Solid oak is exactly what it sounds like, and its advantage is longevity — a solid board can be sanded and refinished many times over its life. It moves more with the seasons, so it needs a timber subfloor, a stable environment and a proper expansion gap around the perimeter.
Real wood needs to acclimatise in the room before it goes down, normally for several days, and we build that into the schedule rather than fitting straight off the van. If you want the look of oak somewhere it cannot realistically go, such as a bathroom or a busy utility, oak-effect LVT is the sensible alternative.
Yes. The surface you walk on and see is solid oak, usually between 3mm and 6mm thick, bonded to a plywood core beneath. It is not a photographic print like laminate. The layered core simply makes the board far more stable than a solid plank.
Engineered oak yes, solid oak generally no. The layered construction of engineered board copes with the heat cycling without cupping or gapping, whereas solid timber moves too much. Board width matters too — narrower boards are more forgiving, and the floor temperature must stay within the manufacturer's limit.
A solid oak floor can usually be sanded five or six times over its life, which is why these floors last generations. Engineered board depends entirely on its wear layer — a 6mm top layer will take two or three sandings, while a 3mm layer will take one at most. It is worth knowing that number before you buy.
Lacquer sits on the surface as a hard film and needs little maintenance, but when it wears through the whole floor has to be sanded and recoated. Oil soaks into the timber, looks more natural and can be patch-repaired in a single area, at the cost of re-oiling every year or two. Busy family homes usually do better with lacquer.
Yes, and skipping it is the most common cause of a wood floor failing. Boards need to sit in the room they will be fitted in, in their packaging, until their moisture content matches the house — normally three to seven days. Fitting straight off a cold van is how you end up with gaps in summer or cupping in winter.
Yes, kitchens are fine for engineered oak provided spills are wiped up rather than left to stand. What we would not recommend is solid wood in a kitchen with underfloor heating, or any real wood in a bathroom or wet room. For those, oak-effect LVT gives the same look with none of the risk.
Yes, noticeably. Herringbone and chevron use more material because of the cutting waste, take considerably longer to set out and lay, and demand a very flat subfloor. Expect the fitting element to be roughly double a straight lay, but it is the most striking floor we fit.
Real wood will mark, and that is part of its character rather than a fault. Brushed and oiled finishes hide marks far better than a high-gloss lacquer, which shows everything. Felt pads on furniture, a doormat at every external door and keeping grit off the floor make more difference than the finish you choose.
Real wood expands and contracts with humidity, so it needs an expansion gap around the entire perimeter, typically 10 to 15mm, hidden by skirting or beading. Blocking that gap with a tight-fitted skirting or a doorway threshold is what causes floors to lift and peak in the middle.
Engineered oak yes, either glued down or floating over an underlay with a damp-proof membrane. Solid oak on concrete needs a plywood subfloor fixing down first, which raises the floor height. We check the moisture content of the slab before committing either way.
We fit oak and engineered wood flooring across Preston, Longridge, Ribchester, Chorley, Leyland, Blackburn, Lytham and the surrounding Lancashire villages. Our areas we cover page has the full list.
contact
Tell us which rooms you are thinking about and we will bring the samples to you, measure up, and put one written price in your hand with fitting included.
Covering Preston, Chorley, Blackburn and across Lancashire